# Ultrasound for Microclots: Can Sound Waves Break Down Amyloid?

> Can ultrasound break down microclots or amyloid fibrils? We read 12 studies: what worked in a dish or in mice, and why home and scanner units differ.

Canonical: https://amyloid-test.com/resources/ultrasound-microclots-amyloid/
Last updated: 2026-11-21
Author: Tim Ottowitz
Evidence level: preclinical

**Short answer:** Only in the lab so far. Ultrasound shrank amyloid microclots on a chip, but mainly at low frequencies (150 to 500 kHz) and with gas bubbles present. At 1 MHz, the frequency of home therapy units, clots barely changed. In mice, 1 MHz brain ultrasound didn't clear amyloid without injected microbubbles. No study has shown ultrasound breaking microclots inside a person.

## Key takeaways

- On a lab chip, ultrasound shrank pig-plasma microclots at 150 kHz, but not at 300 kHz to 1 MHz without added microbubbles.
- In mice, 1 MHz scanning ultrasound cleared brain amyloid only when microbubbles opened the blood-brain barrier.
- At 1 MHz, ultrasound sped up clot-busting drugs in 1990s studies but did almost nothing without them.
- Ultrasound-broken amyloid pieces are still amyloid and can seed new fibrils.
- No human or animal study has tested ultrasound on fibrin amyloid microclots in the body.

People with Long COVID keep asking whether ultrasound can break up [fibrin amyloid microclots](https://amyloid-test.com/resources/what-are-microclots/). On X, some use 1 MHz home therapy units such as the US Pro 2000 on their neck and head, or spend hours under a clinic's imaging scanner. We read the 12 studies behind the idea, mostly in full, so you'll know what was actually tested and what it means for those machines.

## First, what is amyloid and how could sound break it?

Picture a protein as a ribbon. Sometimes ribbons fold the wrong way and stack into stiff, sticky threads called amyloid. In some people's blood, the clotting protein fibrin folds this way and forms tiny clumps that resist being dissolved. That's the idea behind [fibrin amyloid microclots research](https://amyloid-test.com/resources/fibrin-amyloid-microclots-research/).

Ultrasound is sound too high for us to hear. It can shake things in two ways. It can warm tissue a little, and it can make tiny gas bubbles in a liquid swell and wobble.

Those wobbling bubbles stir the liquid around them, and that stirring can tear brittle things apart. Almost every study below turns on whether bubbles were there.

## Can ultrasound break up microclots?

The only microclot studies come from one research group at Openwater, a company building low-frequency ultrasound devices. They made microclots by freezing and thawing pig plasma 12 times, put them on a still chip with no blood flow, and played ultrasound at four frequencies at a gentle strength ([Rasouli, Hartl and Konecky, 2025](https://doi.org/10.3389/fbioe.2025.1604447)).

- **At 150 kHz**, clots shrank from about 20 to about 7 micrometres across. Bubbles formed by themselves from gas already dissolved in the plasma.
- **When they removed that gas**, 150 kHz stopped working. No bubbles, no breakup.
- **At 300 kHz, 500 kHz and 1 MHz without added bubbles**, there was no significant change in clot size. In their words, "At 300 kHz and higher frequencies there is no statistically significant change in clot size".
- **With added microbubbles** (the contrast agent used in some scans), 150 to 500 kHz worked well. At 1 MHz, the number of large clots only fell from about 450 to about 350.

A second paper from the same team added clot-busting enzymes ([Rasouli and colleagues, 2026](https://doi.org/10.1007/s11239-025-03220-0)). Every ultrasound run there included microbubbles. Ultrasound plus bubbles cut clot size by more than 60%.

On their own, rtPA, lumbrokinase and nattokinase didn't shrink the clots at all. That fits what we found when we compared [nattokinase and lumbrokinase for microclots](https://amyloid-test.com/resources/nattokinase-lumbrokinase-microclots/).

## What about amyloid in the brain?

Mouse studies tell the same story. In 2015, Australian researchers swept 1 MHz ultrasound across the brains of Alzheimer's model mice while injecting microbubbles ([Leinenga and Götz, 2015](https://doi.org/10.1126/scitranslmed.aaa2512)). The bubbles briefly opened the blood-brain barrier, and the brain's clean-up cells ate the amyloid. Plaques fell.

When the same lab left the bubbles out, the effect vanished. "We found that ultrasound on its own was not sufficient to clear amyloid," they wrote in 2019 ([Leinenga and colleagues, 2019](https://doi.org/10.1016/j.brainresbull.2019.08.002)). A larger 2024 study used 1 MHz and 286 kHz without bubbles for eight weeks. Plaque area didn't change, although the mice's memory got better anyway ([Leinenga and colleagues, 2024](https://doi.org/10.1038/s41380-024-02509-5)).

There's one drug-free positive result. A 2026 Korean study aimed 450 kHz pulses at one side of the brain in five mice for ten 30-minute sessions and found fewer and smaller plaques on that side ([Theranostics, 2026](https://doi.org/10.7150/thno.122123)). It's small, it compares one half of a brain with the other, and a company part-funded it.

In people, amyloid has only fallen when MRI-guided 220 kHz ultrasound and microbubbles were combined with an antibody drug, in three patients ([Rezai and colleagues, 2024](https://doi.org/10.1056/NEJMoa2308719)). For more on what microclots may do in the head, see [microclots in the brain](https://amyloid-test.com/resources/microclots-in-brain/).

## Does breaking amyloid make it go away?

Not by itself. Labs use ultrasound on purpose to snap amyloid fibrils into short "seeds", because the pieces are still amyloid and help new fibrils grow. A 2009 study showed sonication both breaks fibrils into shorter fibrils and turns dissolved protein into new fibrils ([Chatani and colleagues, 2009](https://doi.org/10.1073/pnas.0901422106)).

A 2025 study got around this by sticking tiny droplets to the fibrils that pop into bubbles under ultrasound and hold onto the pieces. Plain 1 MHz ultrasound up to 3 W/cm² did nothing to the amyloid signal in that study: "control samples insonated in the absence of the emulsions did not show a significant reduction in ThT fluorescence" ([Kim and Medina, 2025](https://doi.org/10.1016/j.biomaterials.2025.123146)).

## What does 1 MHz ultrasound do to ordinary clots?

In the 1990s, researchers tested 1 MHz ultrasound on normal blood clots, the kind behind strokes and deep vein clots. Ultrasound made clot-busting drugs like rt-PA work faster. Without the drug, it did almost nothing: 3% lysis or less in the dish ([Francis and colleagues, 1992](https://doi.org/10.1172/JCI116088)) and 6% in rabbits ([Lauer and colleagues, 1992](https://doi.org/10.1161/01.CIR.86.4.1257)).

Microclots are harder still. Long COVID microclots held about eight to nine times more α2-antiplasmin, a brake on clot breakdown, and survived a first round of protein digestion that cleared healthy plasma ([Pretorius and colleagues, 2021](https://doi.org/10.1186/s12933-021-01359-7)). Read more on [why post-vaccination microclots resist fibrinolysis](https://amyloid-test.com/resources/post-vaccination-microclots-fibrinolysis/).

## How do home units and scanners compare with the studies?

| Device or study | Frequency | Strength in a pulse | Bubbles | What happened |
|---|---|---|---|---|
| Home therapy unit (US Pro 2000) | 1 MHz | about 0.22 MPa at every setting (our estimate) | None | Not tested on microclots |
| Clinic imaging scanner | 2 to 12 MHz | about 2 to 5 MPa, in microsecond pulses (our estimate) | None | Not tested on microclots |
| [Microclot chip study](https://amyloid-test.com/resources/microclots-treatment/), no added bubbles | 150 kHz to 1 MHz | 0.11 to 0.30 MPa | Natural gas only | Shrank only at 150 kHz |
| Microclot chip study, with microbubbles | 150 to 500 kHz | 0.11 to 0.21 MPa | Added | Clots down by more than 60% |
| Mouse brain, no bubbles | 1 MHz and 286 kHz | 0.57 to 0.7 MPa | None | No plaque change |
| Mouse brain, with bubbles | 1 MHz | 0.7 MPa | Injected | Plaques cleared by immune cells |
| 1990s clot studies | 1 MHz | up to 8 W/cm² | None | Helped drugs; 3% or less alone |

The home unit's settings (low, medium, high) change how long each pulse is switched on, not how hard it pushes. The 1 MHz chip run at 0.30 MPa, a little above the home unit's estimated 0.22, didn't shrink clots significantly. Imaging scanners push harder in each pulse, but the pulses last millionths of a second, at frequencies 13 to 80 times higher than the 150 kHz that worked on the chip, with no bubbles. No study has used hours of scanning to treat clots.

## Is low-frequency ultrasound safe to try?

Low frequency isn't a free upgrade. In stroke patients, 2 MHz ultrasound plus a clot-busting drug sped early clot opening in one trial ([CLOTBUST, 2004](https://doi.org/10.1056/NEJMoa041175)). A larger follow-up was stopped early because it wasn't working. A 300 kHz version caused bleeding in the brain in 13 of 14 patients, against 5 of 12 on the drug alone ([TRUMBI, 2005](https://doi.org/10.1161/01.STR.0000170707.86793.1a)).

The home unit's own manual warns against using it over the eyes, the carotid artery area or the throat, and on anyone who can't report heat or pain. If you're thinking about any device for microclots, talk to a clinician first, and don't combine it with clot-busting supplements or blood thinners on your own.

## How could you tell whether a device did anything?

You'd need a measurement before and after, the same way each time. The [amyloid fibrin test](https://amyloid-test.com/resources/amyloid-fibrin-test/) page explains how ThT staining works. Our [amyloid test](https://amyloid-test.com/) counts and sizes the glowing, ThT-positive shapes in a finger-prick dried blood sample, and some people order a second kit to compare before and after a treatment.

Be clear about the limits. A ThT count can't tell whether a device removed microclots or only broke them into smaller pieces that still glow, or pieces too small for the microscope. The kit isn't a diagnosis, and it isn't validated against the venous plasma method used in research. A fair test would also need people who got a sham session, and someone scoring the images without knowing who was treated.

## The bottom line

Ultrasound can break amyloid microclots in a dish, under specific conditions: low frequency, gentle pressure and bubbles. Nobody has shown that in a living body. The machines people use at home and in clinics run at frequencies where the dish studies saw little or no effect, without bubbles. If you want to understand your own results first, start with [how to test for microclots](https://amyloid-test.com/resources/how-to-test-for-microclots/).

## FAQ

### Can a home ultrasound device break up microclots?

There's no evidence it can. Home therapy units like the US Pro 2000 run at 1 MHz with no bubbles. In the only microclot study that tested 1 MHz, clots didn't shrink significantly without added microbubbles. Even the stronger 1 MHz settings used in mouse brain studies didn't clear amyloid on their own. Its manual also warns against use over the eyes, the carotid artery area and the throat.

### Does diagnostic ultrasound dissolve amyloid in the blood?

No study shows it. Scanners used for imaging send very short pulses at 2 to 12 MHz. They're used to measure how red cells stack in veins, and in those studies blood flow, not the beam, changed the stacks. No study has found an imaging scan, even a long one, breaking up microclots or amyloid in a living person.

### Why did 150 kHz work better than 1 MHz?

Low-frequency sound makes tiny gas bubbles swell and wobble much more. In the chip study, bubbles grew more than 30-fold at 150 to 300 kHz but less than 2-fold at 1 MHz. The wobbling bubbles stir the fluid and shear the brittle clots apart. When the researchers removed the gas from the plasma, even 150 kHz stopped working.

### Is low-frequency ultrasound safe for the brain?

Not without careful control. In the TRUMBI stroke trial, 300 kHz ultrasound through the skull plus a clot-busting drug caused bleeding in 13 of 14 patients, compared with 5 of 12 on the drug alone, and the trial was stopped. Brain research devices now use precise targeting and strict limits, so a low frequency isn't something to try at home.

### Could the Amyloid Test show whether ultrasound worked?

It can show whether the count and size of glowing, ThT-positive shapes changed between two samples, which is why some people order a second kit to compare before and after. It can't tell whether a device removed microclots or only broke them into smaller pieces that still glow, and it isn't validated against the venous plasma research method.

## Sources

- [Low-intensity ultrasound lysis of amyloid microclots in a lab-on-chip model](https://doi.org/10.3389/fbioe.2025.1604447) (Frontiers in Bioengineering and Biotechnology, 2025)
- [Investigation of the synergistic effect of enzymatic and ultrasound-induced amyloid microclot degradation](https://doi.org/10.1007/s11239-025-03220-0) (Journal of Thrombosis and Thrombolysis, 2026)
- [Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer's disease mouse model](https://doi.org/10.1126/scitranslmed.aaa2512) (Science Translational Medicine, 2015)
- [Scanning ultrasound in the absence of blood-brain barrier opening is not sufficient to clear β-amyloid plaques in the APP23 mouse model of Alzheimer's disease](https://doi.org/10.1016/j.brainresbull.2019.08.002) (Brain Research Bulletin, 2019)
- [Scanning ultrasound-mediated memory and functional improvements do not require amyloid-β reduction](https://doi.org/10.1038/s41380-024-02509-5) (Molecular Psychiatry, 2024)
- [Ultrasound blood-brain barrier opening and aducanumab in Alzheimer's disease](https://doi.org/10.1056/NEJMoa2308719) (New England Journal of Medicine, 2024)
- [Clearance of amyloid plaque via focused ultrasonication in a mouse model of Alzheimer's disease](https://doi.org/10.7150/thno.122123) (Theranostics, 2026)
- [Ultrasonication-dependent production and breakdown lead to minimum-sized amyloid fibrils](https://doi.org/10.1073/pnas.0901422106) (PNAS, 2009)
- [Enhancement of fibrinolysis in vitro by ultrasound](https://doi.org/10.1172/JCI116088) (Journal of Clinical Investigation, 1992)
- [Effect of ultrasound on tissue-type plasminogen activator-induced thrombolysis](https://doi.org/10.1161/01.CIR.86.4.1257) (Circulation, 1992)
- [Ultrasonic disruption of circulating amyloid β aggregates via phase-change peptide nanoemulsions](https://doi.org/10.1016/j.biomaterials.2025.123146) (Biomaterials, 2025)
- [Persistent clotting protein pathology in Long COVID/Post-Acute Sequelae of COVID-19 (PASC) is accompanied by increased levels of antiplasmin](https://doi.org/10.1186/s12933-021-01359-7) (Cardiovascular Diabetology, 2021)
- [Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke (CLOTBUST)](https://doi.org/10.1056/NEJMoa041175) (New England Journal of Medicine, 2004)
- [Transcranial low-frequency ultrasound-mediated thrombolysis in brain ischemia (TRUMBI)](https://doi.org/10.1161/01.STR.0000170707.86793.1a) (Stroke, 2005)

## Related

- [What Are Amyloid Microclots? Definition, Causes and Evidence](https://amyloid-test.com/resources/what-are-microclots/)
- [How to Test for Microclots: Methods, Labs and Limits](https://amyloid-test.com/resources/how-to-test-for-microclots/)
- [Micro Blood Clots Symptoms: Microclots Symptoms Guide](https://amyloid-test.com/resources/microclots-symptoms-guide/)
